Artesyn LCM1500 Bulk Front End AC-DC Single Output Power Supply

Artesyn LCM1500 Bulk Front End AC-DC Single Output Power Supply










UP TO 1500 WATTS OF CONTINUOUS OUTPUT POWER

PEI-Genesis now offers Artesyn Embedded Technologies’, formerly Emerson Network Power's Embedded Computing & Power business, LCM1500 Bulk Front End AC-DC Single Output Power Supplies. The LCM1500 2U power supply provides a low-cost solution to industrial, military, entertainment and medical applications with single output power requirements. The LCM1500 utilizes a smart fan for self-contained thermal management at very low acoustic noise levels. Digital DSP software control allows for a high-level of modification flexibility. Voltage output for the series ranges from 10.8V - 52.8V at a continuous output power of 1500W. The efficiency of the LCM1500 is greater than 91 percent at full load (230 Vac nominal input), and is at least 80 percent at all loads higher than 25 percent. The LCM1500 also provides an optional 5V Standby and many optional I/O configurations. The -40°F (-40°C) to 158°F (70°C) operation ratings and 2.4" x 5" x 10" (61 x 127 x 254 mm) enclosed form factor make the LCM perfect for rugged, non-environmental applications where the unit will be mounted to bulkheads and sheets of metal.

PEI-Genesis offers the ability to create the power supplies unique to your specifications within a 5 day turnaround. Browse the LCM1500 series product specifications below or contact us. Our engineers can discuss the power solution we can create for you.
Click to download PDF

Artesyn Embedded Technologies

FEATURES

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 1500W FEATURES

  • 1500 W output power

  • Low Cost

  • 2.5” x 5.2” x 10.0”

  • 12 Watts Per Cubic Inch

  • Industrial/Medical Safety

  • -40 °C to 70 °C with derating

  • Optional 5 V @ 2 A Housekeeping

  • High Efficiency: 89% Typical

  • Variable speed “Smart Fans”

  • DSP controlled

  • Conformal coat option

  • ± 10% adjustment range

  • Margin programming

  • OR-ing FET


INPUT

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 1500W INPUT

Input

Input Range

90 - 264 Vac (Operating), 115/230 Vac (Nominal)

Input Frequency

47 - 440 Hz, Nominal 50/60

Input Fusing

Internal 20 A fuses, both lines fused

Inrush Current

≤ 25 A peak, either hot or cold start

Power Factor

0.99 typical, meets EN61000-3-2

Harmonics

Meets IEC 1000-3-2 requirements

Input Current

8 A RMS max input current, at 100 Vac

Hold up Time

20 ms minimum for Main O/P, at full rated load

Efficiency

> 91% typical at full Load

Leakage Current

< 0.3 mA at 264 Vac

On/Off Switch Power

N/A

Power Line Transient

MOV directly after the fuse

Isolation

PRI-Chassis 2500 Vdc Basic; PRI-SEC 2500 Vdc Reinforced;
SEC-Chassis 500 Vdc

OUTPUT

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 1500W OUTPUT

Output

Output Rating

See output voltage table

At 90 - 264 Vac

Set Point

± 0.5%

At 90 - 264 Vac

Total Regulation Range

Main output ± 2%

5 Vsb ± 1%

Combined line/load/transient when measured at output terminal

Rated Load

600 W Max

Derate linear to 50% from 50 °C to 70 °C

Minimum Load

Main output @ 0.0 A

5 Vsb @ 0.0 A

No loss of regulation

Output noise (PARD)*

1% max p-p

50 mV max p-p

Main output

5 Vsb output

Output voltage overshoot



No overshoot/undershoot outside the regulation band during on or off cycle



Transient Response



< 300 μSec

50% load step @ 1 A/μs

Step load valid between 10% to 100% of output rating

Recovery time to within 1% of set point at onset of transient

Max Units in Parallel


Up to 10

Short Circuit Protection

Protected, no damage to occur

Bounce mode

Remote Sense


Compensation up to 500 mV

Output Isolation


Standard per safety requirements

Forced Load Sharing

To within 10% of all shared outputs

Analog sharing control

Overload Protection (OCP)

105% to 125%

120% to 170%

Main output

5 Vsb Output

Overvoltage protection (OVP)

125% to 145%

110% to 125%

Main output

5 Vsb Output

Overtemp Protection

10 - 15 °C above safe operating area

Both PFC and output converter monitored



*Measured with a 0.1 μF Ceramic and 10 μF Tantalum Capacitor on any output, 20 MHz

OUTPUT VOLTAGE

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 1500W OUTPUT VOLTAGE TABLE

Output Voltage Table

Model Number


Output



Nominal Output Voltage Set Point

Set Point Tolerance


Adjustment Range


Current
Min


Current
Max


Output Ripple P/P (0-50 deg C)

Max Continuous Power

Combined Line/Load Regulation

LCM1500L

12 V

12 V

± 0.5%

10.8-13.2V

0A

133A

120mV

1500W

2%

LCM1500N

15 V

15 V

± 0.5%

13.5-16.5V

0A

100A

150mV

1500W

2%

LCM1500Q

24 V

24 V

± 0.5%

21.6-26.4V

0A

67A

240mV

1500W

2%

LCM1500R

28 V

28 V

± 0.5%

25.2-30.8V

0A

53.6A

280mV

1500W

2%

LCM1500U

36 V

36 V

± 0.5%

32.4-39.6V

0A

43A

360mV

1500W

2%

LCM1500W

48 V

48 V

± 0.5%

43.2-52.8V

0A

33A

480mV

1500W

2%

ENVIRONMENTAL

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 1500W ENVIRONMENTAL SPECIFICATIONS

Environmental Specifications

Operating Temperature

-40 °C to +70 °C, linear derating to 50% from 50 °C to 70 °C

Storage Temperature

-40 °C to +85 °C

Humidity

20 to 90%, non-condensing. Operating. Conformal coat option available

Fan Noise

< 45 dBA, 80% load at 30 °C “-N” Low Noise Option <35 dBA,80% Load at 30 °C

Altitude

Operating - 16,405 feet (3000m), Storage - 30,000 ft

Shock

MIL-STD-810F 516.5, Procedure I, VI. Storage

Vibration

MIL-STD-810F 514.5, Cat. 4, 10. Storage

SAFETY

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 1500W SAFETEY

Safety



UL

60950-1

508/1598/1433

60601-Ed 3

CSA

60950-1


VDE

60950-1

60601

China

CCC


CB

60950-1

Scheme Report/Cert

 