PEI-Genesis now offers Artesyn Embedded Technologies’, formerly Emerson Network Power's Embedded Computing & Power business, LCM600 Bulk Front End AC-DC Single Output Power Supplies. The LCM600 2U provides a low-cost solution to industrial, medical, military, entertainment, and process automation applications requiring single output power. The LCM600 utilizes a smart fan for self-contained thermal management at very low acoustic noise levels. Digital DSP software control allows for a high-level of modification flexibility. Optional 5 V standby @ 2 A and Diode OR-ing is available along with conformal coating. The -40°F (-40°C) to 158°F (70°C) operation ratings and enclosed form make the LCM perfect for rugged, non-environmental applications where the unit will be mounted to bulkheads and sheets of metal.

Still not convinced? Speak with one of our Engineers to find the right power supply for your application today. We’ll work with you from conception to shipment and have your order ready within 5 days.
Click to download PDF

Artesyn Embedded Technologies

FEATURES

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 600W FEATURES

  • 600 W output power

  • Low Cost

  • 2.4” x 4.5” x 7.5”

  • 7.41 W/cu-in

  • Industrial/Medical Safety

  • -40 °C to 70 °C with derating

  • Optional 5 V @ 2 A Housekeeping

  • High Efficiency: 89% Typical

  • Variable speed “Smart Fans”

  • DSP controlled front end

  • Conformal coat option

  • ± 20% adjustment range

  • Margin programming

  • OR-ing FET

  • Terminal block input option


INPUT

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 600W INPUT

Input

Input Range

85 - 264 VAC (Operating), 115/230 VAC (Nominal)

Input Frequency

47 - 440 Hz, Nominal 50/60

Input Fusing

Internal 10 A fuses, both lines fused

Inrush Current

≤ 25 A peak, either hot or cold start

Power Factor

0.99 typical, meets EN61000-3-2

Harmonics

Meets IEC 1000-3-2 requirements

Input Current

8 A RMS max. input current, at 100 VAC

Hold up Time

20 ms minimum for Main O/P, at full rated load

Efficiency

> 88% typical at full Load

Leakage Current

< 0.3 mA at 264 VAC

On/Off Switch Power

N/A

Power Line Transient

MOV directly after the fuse

Isolation

PRI-Chassis 2500 VDC Basic; PRI-SEC 2500 VDC Reinforced;
SEC-Chassis 500 VDC



OUTPUT

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 600W OUTPUT

Output

Output Rating

See output voltage table

At 90 - 264 VAC

Set Point

± 0.5%

At 90 - 264 VAC

Total Regulation Range

Main output ± 2%

5 Vsb ± 1%

Combined line/load/transient when measured at output terminal

Rated Load

600 W Max.

Derate linear to 50% from 50 °C to 70 °C

Minimum Load

Main output @ 0.0 A

5 Vsb @ 0.0 A

No loss of regulation

Output Noise (PARD)*

1% max. p-p

50 mV max. p-p

Main output

5 Vsb output

Output Voltage Overshoot



No overshoot/undershoot outside the regulation band during on or off cycle



Transient Response



< 300 μSec

50% load step @ 1 A/μs

Step load valid between 10% to 100% of output rating

Recovery time to within 1% of set point at onset of transient

Max Units in Parallel


Up to 10

Short Circuit Protection

Protected, no damage to occur

Bounce mode

Remote Sense


Compensation up to 500 mV

Output Isolation


Standard per safety requirements

Forced Load Sharing

To within 10% of all shared outputs

Analog sharing control

Overload Protection (OCP)

105% to 125%

120% to 170%

Main output

5 Vsb Output

Overvoltage Protection (OVP)

125% to 145%

110% to 125%

Main output

5 Vsb Output

Overtemp Protection

10 - 15 °C above safe operating area

Both PFC and output converter monitored



*Measured with a 0.1 μF Ceramic and 10 μF Tantalum Capacitor on any output, 20 MHz

OUTPUT VOLTAGE

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 600W OUTPUT VOLTAGE TABLE

Output Voltage Table

Model Number*


Output



Nominal Output Voltage Set Point

Set Point Tolerance


Adjustment Range


Current
Min.


Current
Max.


Output Ripple P/P (0-50 deg C)

Max. Continuous Power

Combined Line/Load Regulation

LCM600C

3 V

3 V

± 0.5%

2.0 - 4.0 V

0A

150.0 A

50 mV

600W

2%

LCM600E

5 V

5 V

± 0.5%

4.0 - 6.0 V

0A

120.0 A

50 mV

600W

2%

LCM600L

12 V

12 V

± 0.5%

9.6 - 14.4 V

0A

52.0 A

120 mV

600W

2%

LCM600N

15 V

15 V

± 0.5%

12.0-19.5 V

0A

44.0 A

150 mV

600W

2%

LCM600Q

24 V

24 V

± 0.5%

19.2-28.8 V

0A

27.0 A

240 mV

600W

2%

LCM600U

36 V

36 V

± 0.5%

28.8-43.2 V

0A

16.7 A

240 mV

600W

2%

LCM600W

48 V

48 V

± 0.5%

38.4-57.6 V

0A

14.0 A

280 mV

600W

2%


* Note: Add “-T” for terminal block instead of IEC input.

ENVIRONMENTAL

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 600W ENVIRONMENTAL SPECIFICATIONS

Environmental

Operating Temperature

-40 °C to +70 °C, linear derating to 50% from 50 °C to 70 °C

Storage Temperature

-40 °C to +85 °C

Humidity

20 to 90%, non-condensing. Operating. Conformal coat option available

Fan Noise

< 45 dBA, 80% load at 30 °C

Altitude

Operating - 15,000 ft., Storage - 30,000 ft.

Shock

MIL-STD-810F 516.5, Procedure I, VI. Storage

Vibration

MIL-STD-810F 514.5, Cat. 4, 10. Storage



SAFETY

ARTESYN EMBEDDED TECHNOLOGIES LCM SERIES LCM 600W SAFETEY

Safety



UL

60950-1

508/1598/1433

60601-1

CSA

60950-1


VDE

60950-1

60601


China

60950-1

CCC


CB

60950-1

Scheme Report/Cert



 