Home Excelsys Xgen Hi-Rel XF Series AC-DC Mil-COTS/Harsh Environment Power Supply

Excelsys Xgen XF Series AC-DC Mil-COTS/Harsh Environment Power Supply

Excelsys Xgen XF Series AC-DC Mil-COTS/Harsh Environment Power Supply




CUSTOMIZABLE POWER FOR HARSH ENVIRONMENTS AND MIL-COTS APPLICATIONS

The Excelsys XF series AC-DC Mil-COTS/harsh environment power supply is a highly-flexible field-configurable power supply ultimately delivering customized power in virtually minutes. Its modular architecture allows for fast custom configurations by the user in the field or on the bench during development and qualification. The Excelsys XF series offers power outputs of 400W ( XFA series), 700W (XFB series) and 1000W (XFC series), with up to 12 isolated outputs. Outputs of 1 VDC through 58 VDC and series and parallel combinations of modules are possible. The XF series is shock and vibration resistant to MIL-STD-810G; excellent for harsh conditions and mobile applications. All configurations carry full safety agency approvals, including UL60950 and EN60950 and are fully characterized for EMC according to MIL-STD-461F. EMC Characterization, Shock and Vibration and Thermal Stress reports are available upon request. For full specifications, please see below.

Click to download PDF

Excelsys

FEATURES

EXCELSYS XF SERIES AC-DC MIL-COTS/HARSH ENVIRONMENT POWER SUPPLY FEATURES

  • MIL-STD-810G: Shock & Vibration

  • MIL-STD-461F: EMC

  • Conformal Coated & Ruggedized as standard

  • Operating temperature range of -55 to 70°C

  • 47-440Hz input frequency

  • Anti-Vibration Compound

  • All outputs fully floating

  • Extra low profile: 1U height

  • Ultra high efficiency, up to 91%

  • Plug & Play Power - allows fast custom configuration

  • Series / Parallel of multiple outputs

  • Parallel powerPacs for higher power

  • 5V bias standby voltage provided

  • Individual output control

  • 3 Year Warranty

  • FLEXIMOUNT Flexible mounting system


INPUT

EXCELSYS XF SERIES AC-DC MIL-COTS/HARSH ENVIRONMENT POWER SUPPLY INPUT

Parameter

Conditions/Description

Min.

Nom.

Max.

Units

Input Voltage Range

Universal Input 47-63Hz

Input: 390 - 440Hz

85

90


264

120

VAC

VDC


Power Rating

XFA

XFB

XFC



400

700

1000

W

W

W


Input Current

XFA - 85VAC in 400W out

XFB - 85VAC in 700W out

XFC - 85VAC in 765W out


7.5

9.5

11.5


A

A

A

Inrush Current

230VAC @ 25°C



25

A

Undervoltage Lockout

Shutdown

65


74

VAC


Fusing

XFA - 250V

XFB - 250V

XFC - 250V


F8A HRC

F10A HRC

F12A HRC





OUTPUT

EXCELSYS XF SERIES AC-DC MIL-COTS/HARSH ENVIRONMENT POWER SUPPLY OUTPUT

Parameter

Conditions/Description

Min.

Nom.

Max.

Units

powerMod Power

As per powerMod table






Output Adjustment Range

Manual or electronic

As per powerMod table





Minimum Load



0


A

Line Regulation

For ±10% change from nominal line





±0.1

%

Load & Cross Regulation

For 25% to 75% load change



±0.2

%


Transient Response

For 25% to 75% load change Voltage Deviation

Settling Time



10

250

%

µs


Ripple and Noise

20MHz Bandwidth



100

1

mV pk-pk

% pk-pk

Overvoltage Protection

1st level: Vset Tracking.
2nd level: Vmax (Latching)

110

130

150

%


Overcurrent Protection

Straight line with hiccup activation at <30% of Vnom

See Xgen Designers’ Manual for full details

110



120


%


Remote Sense

Max. line drop compensation (except Xg7, Xg8)





0.5

VDC

Overshoot




2

%

Turn-on Delay

From AC In / Enable signal



600 / 30

ms

Rise Time

Monotonic



5

ms

Hold-Up Time

For nominal output voltages at full load

20





ms

Output Isolation

Output to Output / Output to Chassis

500 / 500





VDC



GENERAL

EXCELSYS XF SERIES AC-DC MIL-COTS/HARSH ENVIRONMENT POWER SUPPLY GENERAL SPECS

Parameter

Conditions/Description

Min.

Nom.

Max.

Units


Isolation Voltage

Input to Output

Input to Chassis

3000

1500



VAC

VAC

Efficiency

230VAC, 1000W @ 24V


91


%

Safety Agency
Approvals

EN60950, UL60950, CSA22.2 No.950 UL File No. E181875









Leakage Current

230VAC, 50Hz, 25°C



1.5

mA

Bias Supply

Always on. Current 250mA

4.8

5

5.2

VDC




Reliability

Telcordia SR-332 at 25°C and full load - powerMod

Telcordia SR-332 at 25°C and full load - powerPac(excludes fans)

MIL-STD-217F at 25°C and full load - powerMod

MIL-STD-217F at 25°C and full load - powerPac (excludes fans)



1020

1057


86

77

kh

kh


kh

kh



EMC

EXCELSYS SERIES AC-DC MIL-COTS/HARSH ENVIRONMENT POWER SUPPLY EMC

Parameter

Standard

Level

Emissions

Conducted (note 5)

EN55011, EN55022, FCC: Level B

Compliant

Radiated (note 5)

EN55011, EN55022, FCC: Level B

Compliant

Harmonic Distortion

EN61000-3-2 Class A & MIL-STD-1399 SECTION 300A

Compliant

Flicker & Fluctuation

EN61000-3-3

Compliant

Immunity

Electrostatic Discharge

EN61000-4-2: Level 2

Compliant

Radiated RFI

EN61000-4-4: Level 3 & MIL-STD-461F

Compliant

Fast Transients-Burst

EN61000-4-4: Level 3

Compliant

Input Line Surges

EN61000-4-5: Level 3 & MIL-STD-1399

Compliant

Conducted RFI

EN61000-4-6: Level 3 & MIL-STD-461F

Compliant

Voltage Dips

EN61000-4-11 & MIL-STD-704

Compliant



ENVIRONMENTAL

EXCELSYS XF SERIES AC-DC MIL-COTS/HARSH ENVIRONMENT POWER SUPPLY ENVIRONMENTAL

Parameter

Conditions/Description

Min.

Nom.

Max.

Units

Operating Temperature


-55


+70

ºC

Storage Temperature


-55


+75

ºC

Derating

Contact us for full temperature deratings









Acoustic Noise



56.5


dBA

Relative Humidity

Non-condensing

5


95

%RH

Shock

3000 Bumps, 10G (16ms) half sine









Vibration

1.5G : MIL-STD-810G

10


500

Hz



NOTES

EXCELSYS XF SERIES AC-DC MIL-COTS/HARSH ENVIRONMENT POWER SUPPLY NOTES

1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.

2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.

3. All specifications at nominal input, full load, 25°C unless otherwise stated.

4. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output.

5. An external filter is required to meet the conducted and radiated emissions requirements for MIL-STD-461F.

 
Welcome
Please enter your Zip code/Country code to give you
up-to-the-minute pricing and availability in your area.

 I accept the terms and conditions of this website.