Features:

  • High Efficiency
  • Full Regulated DC Output
  • Lifetime Expectation >5 Years
  • Hold-up Time >14ms at Full Load
  • Safety Approval-EN60950-1 Class I
  • CEC Compliant
PEI can modify standard power supplies within 5 business days.

Modified options include:

  • Custom Connectors
  • Floating Output
  • Ferrite Cores
  • Custom Imprinting
  • Special Packaging/Labeling
  • Overmolding
  • Output Cord Lengths

Other factory options include:

  • White Case

Model Overview

Elpac Part NumberOutput VoltageOutput CurrentPeak Current1Total Regulation2Typical Efficiency3
FWC5012-760F 12.0V 4.2A 5.0A ±5% 83%
FW5018-760F 18.0V 2.8A 3.3A ±5% 86%
FW5024-760F 24.0V 2.1A 2.5A ±5% 87%
Input
Input Voltage 85 - 264VAC 100 - 240VAC Nominal
Input Frequency 47 – 63Hz
Input Current <1.0A rms
Inrush Current <37A at 230VAC cold start
Zero Load Power Consumption <0.3W
Touch Leakage Current
<200µA @ 132VAC @ 60Hz
<300µA @ 264VAC @ 60Hz
Output
Output Voltage See Table
Total Regulation +/-5%
Minimum Load No minimum load required
Start-Up Delay <250ms
Hold-Up Time >14ms at any input voltage
Ripple & Noise <1% pk-pk ** *
Over Voltage Protection 110-135%
Over Temperature Protection Active - Recoverable; plus Passive - Non Recoverable
Over Current Protection 120% - 180%
Short Circuit Protection Shutdown, auto-restart (hiccup mode)
General
Efficiency Avg Efficiency 86.7% @ 115VAC; 86.9% @ 230VAC
MTBF min. 100,000 hours demonstrated
Size 05.00" (127.0mm) x 3.00" (76.2mm) x 1.30" (33.0mm)
Weight 0.75 lbs (0.34 kg)
Environmental
Operating Temperature 0 – 60°C (Full load to 40°C, derate linearly to 50% load at 60°C)
Storage Temperature -40°C to +85°C
Relative Humidity 5-95%, non-condensing
Cooling Natural Convection
Vibration All units production tested to 19.6m/s2
EMC & Safety
Emissions FCC Class B, CISPR22 Class B EN61000-3-2, -3
Immunity EN61000-4-2, -3, -4, -5, -6, -8, -11
Certified by TUV to the following:
cTUVus
UL 60950-1
CAN/CSA-22.2 No.60950-1
CB per IEC60950-1
CE marked to LVD & EMC Directive

Notes

  • *Ripple and noise measured with 20MHz bandwidth; 10μF tantalum capacitor in parallel with a 0.1μF ceramic capacitor.

Input / Output Configuration

Input Configuration
Standard Input Cable 6 ft cable with US standard (Nema 5-15) 3 prong connector
Connection on Power Supply Body IEC 320 C14 Receptacle
Output Configuration
Standard Output Cable 6 ft.
Cord Size 2x16awg zip
Connector (PSU side) Switchcraft 760 or equivalent
Mating Connector Switchcraft 712A or equivalent
Output Pin Assignments
Center +v1
Outside Return

 