Home Elpac by ICCNexergy 40 Watt Medical MW40

40 Watt Medical MW40

ICCNexergey MW40

Features:

  • High Efficiency: Level V
  • Fully Regulated DC Output
  • Lifetime Expectation >5 Years
  • Hold-up Time >16ms at Full Load
  • Safety Approval - EN60601-1 Class I
PEI can modify standard power supplies within 5 business days.

Modified options include:

  • Custom Connectors
  • Ferrite Cores
  • Custom Imprinting
  • Special Packaging/Labeling
  • Overmolding
  • Output Cord Lengths

Other factory options include:

  • Grounded Output
  • White Case

Model Overview

Elpac Part NumberOutput VoltageOutput CurrentPeak Current1Total Regulation2Typical Efficiency3
MW4009-760F-NC-BK 9.0V 4.4A 5.3A ±5% 84%
MW4012-760F-NC-BK
12.0V
3.3A
4.0A ±5% 86%
MW4015-760F-NC-BK 15.0v 2.6A 3.2A ±5% 87%
MW4018-760F-NC-BK
18.0V
2.2A 2.6A ±5% 87%
MW4024-760F-NC-BK 24.0V 1.7A
2.0A
±5% 88%
Input
Input Voltage 85-264VAC; 100-240VAC Nominal
Input Frequency 47-63Hz
Input Current <1A rms
Inrush Current <37A at 230VAC cold start
Zero Load Power Consumption 0.3W
Touch Leakage Current
<50µA @ 132VAC @ 60Hz
<75µA @ 264VAC @ 60Hz
Output
Output Voltage See Model Overview Table
Total Regulation +/-5%
Minimum Load No minimum load required
Start-Up Delay <.25s
Hold-Up Time >20ms
Ripple & Noise <1% pk-pk ** *
Over Voltage Protection 110-135%
Over Temperature Protection Active - Recoverable; plus Passive - Non Recoverable
Over Current Protection 120 - 180%
Short Circuit Protection Shutdown, auto-restart (hiccup mode)
General
Efficiency Avg Efficiency 86.4% @ 115VAC; 85.7% @ 230VAC
MTBF min. 200,000 hours demonstrated
Size 5.0 (127.0mm) x 3.0 (76.2 mm) x 1.3 (33.0mm)
Weight 0.8 lbs (.36 kg)
Environmental
Operating Temperature 0 - 40C, linearly derated to 50% load at 60C
Storage Temperature -40°C to +85°C
Relative Humidity 5-95%, non-condensing
Cooling Natural Convection
Vibration All units production tested to 19.6m/s2
EMC & Safety
Emissions FCC class B, CISPR11 class B EN61000-3-2, -3
Immunity EN61000-4-2, -3, -4, -5, -6, -8, -11
Certified by:
cTUVus
UL 60601-1
CAN/CSA-22.2 No.601.1-M90
CB per IEC60601-1
CE marked to LVD

Notes

  • 1 Maximum peak load (28.8W) lasting 500ms with a maximum 10% duty cycle.
  • 2 Includes initial setting, line regulation, load regulation, and thermal drift.
  • 3 Typical at 115VAC (including output cable).
  • Ripple and noise measured with 20MHz bandwidth; 10μF tantalum capacitor in parallel with a 0.1μF ceramic capacitor.

Input / Output Configuration

Input Configuration
Standard Input Cable Not Provided
Connection on Power Supply Body IEC 320 C14 Receptacle
Output Configuration
Standard Output Cable 6 ft.
Cord Size 2x16awg
Connector (PSU side) Switchcraft 760 or equivalent
Mating Connector Switchcraft 712A or equivalent
Output Pin Assignments
Center +v1
Outside Return

 
Welcome
Please enter your Zip code/Country code to give you
up-to-the-minute pricing and availability in your area.

 I accept the terms and conditions of this website.