SEE ELPAC BY ICCNEXERGY MWA020 CLASS I FOR NEW DESIGNSThe Elpac by ICCNexergy 12W AC-DC Medical Desktop Power Supply – MW12 Series is not recommended for new designs. Please see the Elpac by ICCNexergy MWA020 Class I as a drop-in replacement. For details on the Elpac by ICCNexergy MW12 series, please see the product specifications below. |
|||
|
PART NUMBERELPAC BY ICCNEXERGY 12W AC-DC MEDICAL DESKTOP POWER SUPPLY – MW12 SERIES PART NUMBERS Elpac Output Output Peak Total Typical Efficiency3 MW1212-760-NC-BK 12.0V 1.0A 1.2A ±5% 78% MW1224-760-NC-BK 24.0V 0.5A 0.6A ±5% 78% Notes: 1 Maximum peak load (14.4W) lasting 500ms with a maximum 10% duty cycle 2 Includes initial setting, line regulation, load regulation, and thermal drift 3 Typical at 115VAC (including output cable) INPUTELPAC BY ICCNEXERGY 12W AC-DC MEDICAL DESKTOP POWER SUPPLY – MW12 SERIES INPUT Input Input Voltage 85 - 264VAC 100 - 240VAC Nominal Input Frequency 47 – 63Hz Input Current < 0.5A rms Inrush Current < 37A at 230VAC cold start Zero Load Power Consumption 0.97W Touch Leakage Current < 100µA @ 132VAC @ 60Hz OUTPUTELPAC BY ICCNEXERGY 12W AC-DC MEDICAL DESKTOP POWER SUPPLY – MW12 SERIES OUTPUT Output Output Voltage See Part Number Table Total Regulation +/-5% Minimum Load No minimum load required Start-Up Delay < 1s Hold-Up Time > 20ms Ripple & Noise < 1% pk-pk * Over Voltage Protection 110 - 135% Over Temperature Protection Active - Recoverable; plus Passive - Non Recoverable Over Current Protection 120 - 180% Short Circuit Protection Shutdown, auto-restart (hiccup mode) Note: * Ripple and noise measured with 20MHz bandwidth; 10μF tantalum capacitor in parallel with a 0.1μF ceramic capacitor. GENERALELPAC BY ICCNEXERGY 12W AC-DC MEDICAL DESKTOP POWER SUPPLY – MW12 SERIES GENERAL SPECS General Efficiency Avg Efficiency 78.1% @ 115VAC; 77.3% @ 230VAC MTBF min. 200,000 hours demonstrated Size 3.35" (85.0mm) x 1.97" (50.0mm) x 1.30" (33.0mm) Weight 0.45 lbs (.20 kg) ENVIRONMENTALELPAC BY ICCNEXERGY 12W AC-DC MEDICAL DESKTOP POWER SUPPLY – MW12 SERIES ENVIRONMENTAL Environmental Operating Temperature 0 – 60°C (Full load to 40°C, derate linearly to 50% load at 60°C) Storage Temperature -40°C to +85°C Relative Humidity 5 - 95%, non-condensing Cooling Natural Convection Vibration All units production tested to 19.6m/s2 EMC & SAFETYELPAC BY ICCNEXERGY 12W AC-DC MEDICAL DESKTOP POWER SUPPLY – MW12 SERIES EMC & SAFETY EMC & Safety Emissions FCC class B, CISPR11 class B EN61000-3-2, -3 Immunity EN61000-4-2, -3, -4, -5, -6, -8, -11
cTUVus |