350 Watt ITE Open Frame FXA350

350 Watt ITE Open Frame FXA350

Features:

  • High Efficiency: Level V
  • Wide Range AC Input
  • Power Factor Correction
  • +5 Standby & Fan Power
  • Fully Regulated DC Output
  • EISA and CEC Compliant
  • Grounded Output
  • ITE and Medical Grade Approval
PEI can modify standard power supplies within 5 business days.

Model Overview

Elpac Part NumberOutput VoltageOutput Current1Typical Efficiency2
FXA350012A 12.0V 20A 88%
FXA350015A 15.0V 16.5A 88%
FXA350024A 24.0V 10.5A 88%
FXA350028A 28.0V 9.0A 89%
FXA350048A
48.0V
5.3A 88%
Input
Input Voltage 85 - 264VAC 100 - 240VAC Nominal
Input Frequency 47 – 63Hz
Input Current <5A rms
Inrush Current <37A at 230VAC cold start
Power Factor
>0.98
Zero Load Power Consumption <0.75W
Touch Leakage Current
<200µA @ 132VAC @ 60Hz
<300µA @ 264VAC @ 60Hz
Output
Output Voltage See Table
Total Regulation +/-5%
Minimum Load No minimum load required
Start-Up Delay <1s
Hold-Up Time >24ms at any Input Voltage
Ripple & Noise <1% pk-pk ** *
Over Voltage Protection 110-135%
Over Temperature Protection Active - Recoverable; plus Passive - Non Recoverable
Over Current Protection 120 - 180%
Short Circuit Protection Shutdown, auto-restart (hiccup mode)
General
Efficiency Avg Efficiency 88.5% @ 115VAC; 90.6% @ 230VAC
MTBF min. 200,000 hours demonstrated
Size 8.00" x 5.00" x 1.50" | 203.2mm x 127mm x 38.1mm
Weight 2.1 lbs (0.95 kg)
Environmental
Operating Temperature 0 – 70°C (Full load to 50°C, derate linearly to 50% load at 70°C)
Storage Temperature -40°C to +85°C
Relative Humidity 5-95%, non-condensing
Cooling Natural Convection (250W) or Forced Air (350W)
Vibration All units production tested to 19.6m/s2
EMC & Safety
Emissions FCC class B, CISPR22 class B EN61000-3-2, -3
Immunity EN61000-4-2, -3, -4, -5, -6, -8, -11
Certified by TUV to the following:
cTUVus
UL 60950-1
CAN/CSA-22.2 No.60950-1
CB per IEC60950-1
CE marked to LVD

Notes

1 With convection cooling. Peak load (350W) lasting 500ms with a maximum 10% duty cycle.
2 Typical at 115VAC and full load.
* Ripple and noise measured with 20MHz bandwidth; 10μF tantalum capacitor in parallel with a 0.1μF ceramic capacitor.

Input / Output Configuration

Input Configuration (H1)
Connection on Power Supply Body                                                                      
JITE p/n BTB555-10-03 Barrier Strip, M3 screws
Pin 1
AC Line
Pin 2
AC Neutral
Pin 3 Ground
Output Configuration (H4)
Connector (PSU side) JITE p/n BTB555-10-04 Barrier Strip, M3 screws
Pin 1
+V1
Pin 2 +V1
Pin 3 Return
Pin 4 Return
Signal Configuration (H2)
Connector
AMP P/N 640456-8 or equivalent
Mating Connector AMP p/n 640440-8 or equivalent
Pin 1
DC-Good / TTL high when DC is within regulation   
Pin 2
AC Fail / TTL high when AC is present;
min. 8ms warning before loss of DC output
Pin 3
Remote On/Off / Connect to Pin 7 (Rtn) to enable power supply
Pin 4 + Sense / Must be connected to output, either at H4 connector,
or at point of load. Will compensate for up to 500mV cable drop.
Pin 5 - Sense / Must be connected to output, either at H4 connector,
or at point of load. Will compensate for up to 500mV cable drop.
Pin 6 No Connection
Pin 7 Return for Remote on/off and +5V Standby
Pin 8
Return to Pin 7 for +5V @ 1.0A Standby output
Fan Configuration (H3)
Connector AMP P/N 640456-8 or equivalent
Mating Connector AMP p/n 640440-8 or equivalent
Pin 1 +V / Fan output will adjust from +5V to +12V depending on ambient temperature.
Pin 2 +V / Fan output will adjust from +5V to +12V depending on ambient temperature.

 