Home Elpac by ICCNexergy 250 watt medical open frame msmp250

250 watt medical open frame msmp250

Features:

  • High Efficiency: Level V
  • Wide Range AC Input
  • Power Factor Correction
  • +5V Standby & Fan Power
  • Fully Regulated DC Output
  • EISA and CEC Compliant
  • Floating Output
  • ITE and Medical Grade Approval
PEI can modify standard power supplies within 5 business days.

Model Overview

Elpac Part NumberOutput VoltageOutput Current1Forced Air Current2+5V Standby Output Current3
Adjustable Fan Output Current4
Typical Efficiency5
MSMP25012F 12.0V 20.0A 28.0A 1.0A

0.35A

88%
MSMP25015F 15.0V 16.5A 23.0A 1.0A

0.35A

88%
MSMP25024F
24.0V
10.5A
14.5A
1.0A

0.35A

88%
MSMP25028F 28.0V 9.0A 12.5A 1.0A

0.35A

89%
MSMP25048F
48.0V
5.3A
7.4A
1.0A

0.35A

88%
Input
Input Voltage 85 – 264VAC 100 – 240VAC Nominal
Input Frequency 47 – 63Hz
Input Current <5A rms
Inrush Current <37A at 230VAC cold start
Power Factor
>0.98
Zero Load Power Consumption
0.75W
Touch Leakage Current
<200µA @ 132VAC @ 60Hz
<300µA @ 264VAC @ 60Hz
Output
Output Voltage See Table
Total Regulation +/-5%
Minimum Load No minimum load required
Start-Up Delay <1s
Hold-Up Time >24ms at any input voltage
Ripple & Noise <1% pk-pk ** *
Over Voltage Protection 110-135%
Over Temperature Protection Active - Recoverable; plus Passive - Non Recoverable
Over Current Protection 120 - 180%
Short Circuit Protection shutdown, auto-restart (hiccup mode)
General
Efficiency Avg Efficiency 88.5% @ 115VAC; 90.6% @ 230VAC
MTBF min. 200,000 hours demonstrated
Size 8.00" (203.2mm) x 5.00" (127mm) x 1.50" (38.1mm)
Weight 2.1 lbs (0.95 kg)
Environmental
Operating Temperature 0 – 70°C (Full load to 50°C, derate linearly to 50% load at 70°C)
Storage Temperature -40°C to +85°C
Relative Humidity 5-95%, non-condensing
Cooling Natural Convection (250W) or Forced Air (350W)
Vibration All units production tested to 19.6m/s2
EMC & Safety
Emissions FCC class B, CISPR11 class B EN61000-3-2, -3
Immunity EN61000-4-2, -3, -4, -5, -6, -8, -11
Certified by TUV to the following:
cTUVus
UL 60601-1
CAN/CSA-22.2 No.601.1-M90*
CB per IEC60601-1
CE marked to LVD

Notes

  • 1 With convection cooling. Peak load (350W) lasting up to 500ms with a maximum 10% duty cycle.
  • 2 Sustained output current with minimum 100 LFM.
  • 3 Output present when ever AC input is applied.
  • 4 Output self adjusting dependant on ambient temperature. Range of 5 to 13V over 25˚C to 50˚C ambient.
  • 5 Typical at 115VAC.
  • * Ripple and noise measured with 20MHz bandwidth; 10μF tantalum capacitor in parallel with a 0.1μF ceramic capacitor.

 

Input / Output Configuration

Input Configuration (H1)
Connection on Power Supply Body JITE p/n BTB555-10-03 Barrier Strip, M3 screws
Pin 1
AC Line
Pin 2
AC Neutral
Pin 3
Ground
Output Configuration (H4)
Connector (PSU side)
JITE p/n BTB555-10-04 Barrier Strip, M3 screws
Pin 1
+V1
Pin 2
+V1
Pin 3
Return
Pin 4
Return
Signal Configuration (H2)
Connector
AMP P/N 640456-8 or equivalent
Mating Connector AMP p/n 640440-8 or equivalent
Pin 1 DC-Good / TTL high when DC is within regulation
Pin 2
AC-Fail / TTL high when AC is present;
Pin 3
Remote On/Off / Connect to Pin 7 (Rtn) to enable power supply
Pin 4
+Sense / Must be connected to output, either at H4 connector, or at point of load.
Will compensate for up to 500mV cable drop.
Pin 5 - Sense / Must be connected to output, either at H4 connector, or at point of load.
Will compensate for up to 500mV cable drop.
Pin 6
no connection
Pin 7
Return for Remote on/off and +5V Standby
Pin 8
Return to Pin 7 for +5V @ 1.0A Standby output
Fan Configuration (H3)
Connector
AMP P/N 640456-8 or equivalent
Mating Connector AMP p/n 640440-8 or equivalent
Pin 1 +V / Fan output will adjust from +5V to +12V depending on ambient temperature.
Pin 2
-V / Fan output will adjust from +5V to +12V depending on ambient temperature.

 

 