Home Elpac by ICCNexergy 80 Watt Medical Open Frame MTB080

80 Watt Medical Open Frame MTB080

Features:

  • High Efficiency: Level V
  • High Power Density 12.5W/in3
  • Output Floating
  • Lifetime Expectation >5 years
  • Hold-up Time >28ms at Full Load
  • Medical Approval - EN60601-1 Class I
PEI can modify standard power supplies within 5 business days.

Model Overview

Elpac Part NumberOutput VoltageOutput Current1Peak Current2Total Regulation3Typical Efficiency4
MTB080009A 9.0V
7.2A
10.0A
±5% 88%
MTB080012A 12.0V
6.7A
8.3A
±5% 90%
MTB080015A 15.0V
5.4A
6.7A
±5% 90%
MTB080024A 24.0V 3.4A
4.2A
±5% 91%
Input
Input Voltage 85 – 264VAC 100 – 240VAC Nominal
Input Frequency 47 – 63Hz
Input Current <2A rms
Inrush Current <37A at 230VAC cold start
Zero Load Power Consumption <0.3W
Earth Leakage Current (Typical)
<75µA @ 132VAC @ 60Hz
<120µA @ 264VAC @ 60Hz
Patient Leakage Current
<40µA @ 132VAC @ 60Hz
<60µA @ 264VAC @ 60Hz
Output
Output Voltage See Table
Total Regulation +/-5%
Minimum Load No minimum load required
Start-Up Delay <0.2s
Hold-Up Time >28ms at full load
Ripple & Noise <1% pk-pk ** *
Over Voltage Protection 120-150%
Over Temperature Protection Active - Recoverable; plus Passive - Non Recoverable
Over Current Protection 110 - 190%
Short Circuit Protection shutdown, auto-restart (hiccup mode)
General
Efficiency Avg Efficiency 89.6% @ 115VAC; 90.3% @ 230VAC
MTBF min. 200,000 hours demonstrated
Size 4.00" x 2.00" x 1.01" | 101.6mm x 50.8mm x 25.7mm
Weight 0.37 lbs (.166 kg)
Power Density
12.5W/in3
Environmental
Operating Temperature 0 – 50°C (Full load to 50°C, derate linearly to 50% load at 70°C)
Storage Temperature -40°C to +85°C
Relative Humidity 5-95%, non-condensing
Cooling Natural Convection
Vibration All units production tested to 19.6m/s2
EMC & Safety
Emissions FCC class B, CISPR11 class B EN61000-3-2, -3
Immunity EN61000-4-2, -3, -4, -5, -6, -8, -11
Certified by TUV to the following:
cTUVus
UL 60601-1
CAN/CSA-22.2 No.601.1-M90*
CB per IEC60601-1
CE marked to LVD

Notes

  • 1 Maximum load current with natural convection cooling
  • 2 Maximum peak load lasting up to 4 seconds with natural convection cooling, or maximum continuous output current with minimum 5 CFM airflow.
  • 3 Includes initial setting, line regulation, load, regulation, and thermal drift.
  • 4 Typical at 115VAC and full load (65W)
  • * Ripple and noise measured with 20MHz bandwidth; 10μF tantalum capacitor in parallel with a 0.1μF ceramic capacitor.

Input / Output Configuration

Input Configuration
Connection on Power Supply Body
AMP p/n 640445-3 (or equivalent)
Mating Connector
AMP p/n 640250-6 (or equivalent)
Output Configuration
Connector (PSU Side)
AMP p/n 640445-6 (or equivalent)
Cord Size AMP p/n 640250-6 (or equivalent)
Input Pin Assignments (P1)
Pin 1 AC Line
Pin 2 <not assembled>
Pin 3
AC Neutral
Output Pin Assignments (P2)
Pin 1 +Vout
Pin 2 +Vout
Pin 3
Return
Pin 4
Return
Pin 5
N/C
Pin 6
N/C

 