250W OPEN FRAME POWER RATED TO EN60601-1The Elpac by ICCNexergy 250W AC-DC Medical Open Frame Power Supply – MSMP250 Series offers power output of 250 watts (up to 350 watts with forced air cooling) with standard output voltages of 12V, 15V, 24V, 28V and 48V. This 250W internal power supply accepts universal input voltage of 85 – 264 VAC. The MSMP250 Series meets Medical Approval EN60601-1. For full details on the Elpac by ICCNexergy 250W AC-DC Medical Open Frame Power Supply – MSMP250 Series, please see the product specifications below. |
|||
|
FEATURESELPAC BY ICCNEXERGY 250W AC-DC MEDICAL OPEN FRAME POWER SUPPLY – MSMP250 SERIES FEATURES
PART NUMBERELPAC BY ICCNEXERGY 250W AC-DC MEDICAL OPEN FRAME POWER SUPPLY – MSMP250 SERIES PART NUMBERS
Elpac Output Output Forced Air Current2 +5V Standby Output Current3 Adjustable Fan Output Current4 Typical Efficiency5 MSMP25012F 12.0V 20.0A 28.0A 1.0A 0.35A 88% MSMP25015F 15.0V 16.5A 23.0A 1.0A 0.35A 88% MSMP25024F 24.0V 10.5A 14.5A 1.0A 0.35A 88% MSMP25028F 28.0V 9.0A 12.5A 1.0A 0.35A 89% MSMP25048F 48.0V 5.3A 7.4A 1.0A 0.35A 88% Notes: 1 With convection cooling. Peak load (350W) lasting up to 500ms with a maximum 10% duty cycle 2 Sustained output current with minimum 100 LFM 3 Output present when ever AC input is applied 4 Output self adjusting dependant on ambient temperature. Range of 5 to 13V over 25˚C to 50˚C ambient 5 Typical at 115VAC INPUTELPAC BY ICCNEXERGY 250W AC-DC MEDICAL OPEN FRAME POWER SUPPLY – MSMP250 SERIES INPUT Input Input Voltage 85 - 264VAC 100 - 240VAC Nominal Input Frequency 47 - 63Hz Input Current < 5A rms Inrush Current < 37A at 230VAC cold start Power Factor > 0.98 Zero Load Power Consumption 0.75W Touch Leakage Current < 200µA @ 132VAC @ 60Hz OUTPUTELPAC BY ICCNEXERGY 250W AC-DC MEDICAL OPEN FRAME POWER SUPPLY – MSMP250 SERIES OUTPUT Output Output Voltage See Part Number Table Total Regulation +/-5% Minimum Load No minimum load required Start-Up Delay < 1s Hold-Up Time > 24ms at any input voltage Ripple & Noise < 1% pk-pk ** * Over Voltage Protection 110 - 135% Over Temperature Protection Active - Recoverable; plus Passive - Non Recoverable Over Current Protection 120 - 180% Short Circuit Protection shutdown, auto-restart (hiccup mode) Note: * Ripple and noise measured with 20MHz bandwidth; 10μF tantalum capacitor in parallel with a 0.1μF ceramic capacitor. GENERALELPAC BY ICCNEXERGY 250W AC-DC MEDICAL OPEN FRAME POWER SUPPLY – MSMP250 SERIES GENERAL SPECS
General Efficiency Avg Efficiency 88.5% @ 115VAC; 90.6% @ 230VAC MTBF min. 200,000 hours demonstrated Size 8.00" (203.2mm) x 5.00" (127mm) x 1.50" (38.1mm) Weight 2.1 lbs (0.95 kg) ENVIRONMENTALELPAC BY ICCNEXERGY 250W AC-DC MEDICAL OPEN FRAME POWER SUPPLY – MSMP250 SERIES ENVIRONMENTAL Environmental Operating Temperature 0 – 70°C (Full load to 50°C, derate linearly to 50% load at 70°C) Storage Temperature -40°C to +85°C Relative Humidity 5 - 95%, non-condensing Cooling Natural Convection (250W) or Forced Air (350W) Vibration All units production tested to 19.6m/s2 EMC & SAFETYELPAC BY ICCNEXERGY 250W AC-DC MEDICAL OPEN FRAME POWER SUPPLY – MSMP250 SERIES EMC & SAFETY EMC & Safety Emissions FCC class B, CISPR11 class B EN61000-3-2, -3 Immunity EN61000-4-2, -3, -4, -5, -6, -8, -11
cTUVus |